GNUSTEP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Counter,
IpAddress,
enterprises
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC;
gnustep MODULE-IDENTITY
LAST-UPDATED "201202191200Z"
ORGANIZATION "GNUstep"
CONTACT-INFO "Developer GNUstep <gnustep-dev@gnu.org>"
DESCRIPTION "GNUstep MIB"
REVISION "201203161200Z"
DESCRIPTION "First revision of the MIB with PEN
Copyright (C) 2013 Free Software Foundation, Inc.
This file is part of the GNUstep project.
This is free software; you can redistribute it and/or
modify it under the terms of the GNU Lesser General Public
License as published by the Free Software Foundation;
either version 3 of the License, or (at your option)
any later version.
This library is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
See the GNU Library General Public License for more details.
You should have received a copy of the GNU Lesser General
Public License along with this library; if not, write to
the Free Software Foundation, Inc.,
51 Franklin Street, Fifth Floor,
Boston, MA 02111 USA.
"
::= { enterprises 39543 }
alarms OBJECT IDENTIFIER ::= { gnustep 1 }
objects OBJECT IDENTIFIER ::= { gnustep 2 }
traps OBJECT IDENTIFIER ::= { gnustep 3 }
trapsPrefix OBJECT IDENTIFIER ::= { traps 0 }
-----------------------------------------------
-- Definition of the table of active alarms --
-----------------------------------------------
alarmsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "List of active alarms in the platform."
::= { alarms 1 }
--------------------------------------------------------
-- Definition of the tables index --
--------------------------------------------------------
alarmsEntry OBJECT-TYPE
SYNTAX AlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is the index used to redirect each column."
INDEX { notificationID }
::= { alarmsTable 1 }
-----------------------------------------------------------------------
-- Definition of the contents of each record on the table --
-----------------------------------------------------------------------
AlarmsEntry ::=
SEQUENCE {
notificationID INTEGER,
perceivedSeverity INTEGER,
firstEventDate DisplayString,
eventDate DisplayString,
managedObject DisplayString,
eventTypeID INTEGER,
probableCauseID INTEGER,
specificProblem DisplayString,
proposedRepairAction DisplayString,
additionalText DisplayString,
trendIndicator DisplayString
}
-----------------------------------------------
-- Definition of the fields for each record --
-----------------------------------------------
notificationID OBJECT-TYPE
SYNTAX INTEGER ( 0 .. 214748647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Single identifier of each alarm"
::= { alarmsEntry 1 }
perceivedSeverity OBJECT-TYPE
SYNTAX INTEGER {
indeterminate(0),
critical(1),
major(2),
minor(3),
warning(4),
cleared(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Severity of the alarm"
::= { alarmsEntry 2 }
firstEventDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "First alarm concurrence date. Format: YYYYMMDD HH:MM:SS"
::= { alarmsEntry 3 }
eventDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Alarm concurrence date. Format: YYYYMMDD HH:MM:SS"
::= { alarmsEntry 4 }
managedObject OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Single identifier of the alarm object"
::= { alarmsEntry 5 }
eventTypeID OBJECT-TYPE
SYNTAX INTEGER {
communicationsAlarm(2),
environmentalAlarm(3),
equipmentAlarm(4),
processingErrorAlarm(10),
qualityofServiceAlarm(11) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifier of the type of event"
::= { alarmsEntry 6 }
-- The X.733 specification says that the probable cause is an OID, --
-- but for ease of use this MIB defines it as an INTEGER whose value is --
-- that of the rightmost part of the OID defined in X.721 specification. --
-- For example the OID 'adapterError' {9.3.2.0.0.1} is represented as --
-- the integer 1 and 'outOfMemory' {9.3.2.0.0.32} is represented as 32 --
probableCauseID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifier of the possible event cause"
::= { alarmsEntry 7 }
specificProblem OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Additional description of the event cause"
::= { alarmsEntry 8 }
proposedRepairAction OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Solution suggested for the fault detected"
::= { alarmsEntry 9 }
additionalText OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Detailed description of the problem"
::= { alarmsEntry 10 }
trendIndicator OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the alarm trends. For alarms by threshold.
It can have the following values:
0 (zero) ==> First problem incident.
+ ==> The importance of the alarm is higher than the last one sent.
- ==> The importance of the alarm is lower than the last one sent."
::= { alarmsEntry 11 }
--------------------------------------------------------------------
-- Flag for the inhibition of the traps sent during resynchronization--
--------------------------------------------------------------------
resyncFlag OBJECT-TYPE
SYNTAX INTEGER ( 0 ..1 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flag for the inhibition of the traps sent during the resynchronization process.
1 = Resync in progress. The agent must store all traps to send them later on."
::= { alarms 2 }
------------------------------------------------
-- Sequence number of the last trap sent --
------------------------------------------------
trapSequenceNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Trap sequence number"
::= { alarms 3 }
------------------------------------------------
-- Heart beat period --
------------------------------------------------
pollHeartBeat OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the period during which the heart-beat trap is sent. In minutes."
::= { alarms 4 }
---------------------------------------------------
-- Definition of the alarm object table --
---------------------------------------------------
objectsTable OBJECT-TYPE
SYNTAX SEQUENCE OF ObjectsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "List of alarm objects of the platform."
::= { objects 1 }
--------------------------------------------------------
-- Definition of the table index --
--------------------------------------------------------
objectsEntry OBJECT-TYPE
SYNTAX ObjectsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Index of the alarm object table"
INDEX { objectID }
::= { objectsTable 1 }
-----------------------------------------------------------------------
-- Definition of the contents of each record on the table --
-----------------------------------------------------------------------
ObjectsEntry ::=
SEQUENCE
{
objectID DisplayString
}
objectID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Single identifier of the alarm object"
::= { objectsEntry 1 }
----------------------------------------------------------------
-- Definition of the trap sent to the alarm management area --
----------------------------------------------------------------
alarmTrap NOTIFICATION-TYPE
OBJECTS {
trapSequenceNumber,
notificationID,
perceivedSeverity,
firstEventDate,
eventDate,
objectID,
eventTypeID,
probableCauseID,
specificProblem,
proposedRepairAction,
additionalText,
trendIndicator
}
STATUS current
DESCRIPTION "Trap format sent."
::= { trapsPrefix 1 }
END