@ -81,6 +81,7 @@ FluidSynths major version was bumped. The API was reworked, deprecated functions
<strong><span style="color:red">Important changes that may not result in a compilation error but may cause your app to misbehave:</span></strong>
- all public \c fluid_settings_* functions that return an integer which is not meant to be interpreted as bool consistently return either FLUID_OK or FLUID_FAILED
- fluid_settings_setstr() cannot be used to set integer (toggle) settings with "yes" or "no" values anymore. Use fluid_settings_setint() instead, for example: <br /><code>fluid_settings_setint(settings, "synth.reverb.active", 0)</code> instead of <code>fluid_settings_setstr(settings, "synth.reverb.active", "no")</code>
- explicit client unregistering is required for fluid_sequencer_register_client() and fluid_sequencer_register_fluidsynth()
- all public functions consistently receive signed integers for soundfont ids, bank and program numbers
- use unique device names for the "audio.portaudio.device" setting
@ -90,8 +91,9 @@ FluidSynths major version was bumped. The API was reworked, deprecated functions
- all public \c delete_* functions return void and are safe when called with NULL
- the shell command handler was decoupled internally, as a consequence the param list of new_fluid_server() and new_fluid_cmd_handler() was adapted
- \c fluid_settings_set* functions no longer silently register unknown settings but return an error instead
- reverb: roomsize is now limited to an upper threshold of 1.0 to avoid exponential volume increase
- rename fluid_mod_new() and fluid_mod_delete() to match naming conventions: new_fluid_mod() and delete_fluid_mod()
- rename \c fluid_mod_new() and \c fluid_mod_delete() to match naming conventions: new_fluid_mod() and delete_fluid_mod()
- rename chorus getters to match naming conventions: fluid_synth_get_chorus_speed() and fluid_synth_get_chorus_depth()
- fluid_synth_remove_sfont() returns FLUID_OK or FLUID_FAILED
- introduce a separate data type for sequencer client IDs: #fluid_seq_id_t